Description
Here is a matched Quad Mullard Xf2 EL34 tubes made by Mullard in Blackburn, UK.
Detailed description
These Mullard Xf2 EL34 with single halo-getter and welded plate are from the Blackburn production site.The EL34 is a transmitting beam tetrode. The old Mullard production from the past century is known as the ‘crème de la crème’ of the EL34. These tubes deliver superior sonics compared to the Chinese and Russian new production EL34. Sonically many prefer the old welded plate types above the later stapled plate versions. I refer to the many reviews on the web
All three tubes are new and from the same series and have date code Xf2 B 1B4. The fourth tubes is lightly used and has date code 2F3.
The Mullard EL34 Xf2 series is considered by many as an outstanding sounding EL34 tube; a lot better than todays production!
The quad has nice test values and excellent looks. Extremely well matched !
Note: my tubes are often not the cheapest. But is very hard to find better tubes !
Test results
The measurement data below show that the tubes are matched.
Valve
V192 |
Ia (plate current):
Transconductance (Gm): Gas test, Shorts test: |
108 mA
13,0 mA/V OK |
> 100 %
> 100 %
|
Valve
V193 |
Ia (plate current):
Transconductance (Gm): Gas test, Shorts test: |
107 mA
12,9 mA/V OK |
> 100 %
> 100 %
|
Valve
V194 |
Ia (plate current):
Transconductance (Gm): Gas test, Shorts test: |
116 mA
12,8 mA/V OK |
> 100 %
> 100 %
|
Valve
V197
|
Ia (plate current):
Transconductance (Gm): Gas test, Shorts test: |
112 mA
12,7 mA/V OK |
> 100 %
> 100 %
|
Telefunken measuring values for new unused tubes:
- The rated emission value for a new EL34 is: 100 mA.
- The rated transconductance value for a new EL34 is: 11 mA/V .
For Telefunken specs info see last picture
Test conditions & equipment:
Mutual transconductance, plate current, gas and shorts test equipment: AVO Mk IV (Dutch army tester) , AVO Valve Data Manual 23rd edition 1981, RFT stabilised mains, Utracer3+, Philips PE 4832, 2x Korad KA3005P programmable power supply, 2x Keithley 2700 and 2x Fluke 145. Test conditions: Ua (plate voltage) = 250 Volts, Us (screen voltage) = 265 Volts, Ug = -13,5 Volts and Uf = 6,3 V ± 3% (factory conditions). Please read our test page.
Summarized description
Tube type | EL34 |
Quantity of Tubes | One quad |
Brand | Mullard labeled; Mullard |
Manufactured in | Mullard Blackburn, UK |
Date code | Xf2 B 1B4 and one Xf2 B 2F3 |
Plate Construction | Welded grey plate |
Getter Construction | HALO getter |
Print Condition | Excellent; see pictures |
Box included | Original box |
Equivalent tubes: | 6CA7 |
General test results | NOS |
Please read our test and shipping policy before buying !